# Remington

PJM Natural Gas Fired Combustion Turbine · https://askthegrid.com/assets/facilities/remington

Remington is a natural gas-fired power facility with 705.5 MW of EIA-reported nameplate capacity in Fauquier County, Virginia, registered as EIA Plant ID 7838. Virginia Electric & Power Co owns and operates the plant, a subsidiary of Dominion Energy Inc. The plant's generating configuration is four natural-gas-fired combustion turbines, dual-fuel capable of using distillate fuel oil. The facility interconnects at Remington CT substation at 230 kV. Its grid role is peaking generation.

## Key facts

- Technology: Natural Gas Fired Combustion Turbine
- Power capacity: 705.5 MW
- Operating status: operating

## Grid and market context

- ISO/RTO: PJM
- Balancing authority: PJM Interconnection, LLC
- Substation: Remington CT substation
- Point of interconnection: Remington CT substation
- Transmission owner: Dominion Energy
- Interconnection voltage: 230 kV

## Source-backed facts

- Owner logo domain: dominionenergy.com — Power Stations | Dominion Energy · confidence: medium
- Identifiers: [{"value":"7838","system":"EIA plant ID"},{"value":"7838","system":"EPA ORIS / GHGRP plant code"},{"value":"PJM Interconnection, LLC","system":"PJM balancing authority"},{"value":"PJM","system":"PJM power market"},{"value":"7838_G_1","system":"EPA generator unit identifier"},{"value":"7838_G_2","system":"EPA generator unit identifier"},{"value":"7838_G_3","system":"EPA generator unit identifier"},{"value":"7838_G_4","system":"EPA generator unit identifier"},{"value":"W1-074","system":"PJM queue ID — Remington CT 230 kV"},{"value":"AH1-684","system":"PJM queue ID — Remington CT 230 kV"},{"value":"AH1-685","system":"PJM queue ID — Remington CT 230 kV"},{"value":"AH1-693","system":"PJM queue ID — Remington CT 230 kV"}] — Plant Name · confidence: medium
- Identifiers: [{"value":"7838","system":"EIA plant ID"},{"value":"7838","system":"EPA ORIS / GHGRP plant code"},{"value":"PJM Interconnection, LLC","system":"PJM balancing authority"},{"value":"PJM","system":"PJM power market"},{"value":"7838_G_1","system":"EPA generator unit identifier"},{"value":"7838_G_2","system":"EPA generator unit identifier"},{"value":"7838_G_3","system":"EPA generator unit identifier"},{"value":"7838_G_4","system":"EPA generator unit identifier"},{"value":"W1-074","system":"PJM queue ID — Remington CT 230 kV"},{"value":"AH1-684","system":"PJM queue ID — Remington CT 230 kV"},{"value":"AH1-685","system":"PJM queue ID — Remington CT 230 kV"},{"value":"AH1-693","system":"PJM queue ID — Remington CT 230 kV"}] — Reliability Resource Initiative Additional Summaries · confidence: medium
- Identifiers.1: {"value":"7838","system":"EPA ORIS / GHGRP plant code"} — ORIS Crosswalk · confidence: medium
- Identifiers.4: {"value":"7838_G_1","system":"EPA generator unit identifier"} — Plant Name · confidence: medium
- Identifiers.5: {"value":"7838_G_2","system":"EPA generator unit identifier"} — Plant Name · confidence: medium
- Identifiers.6: {"value":"7838_G_3","system":"EPA generator unit identifier"} — Plant Name · confidence: medium
- Identifiers.7: {"value":"7838_G_4","system":"EPA generator unit identifier"} — Plant Name · confidence: medium
- Identifiers.10: {"value":"AH1-685","system":"PJM queue ID — Remington CT 230 kV"} — Reliability Resource Initiative Additional Summaries · confidence: medium
- Identifiers.11: {"value":"AH1-693","system":"PJM queue ID — Remington CT 230 kV"} — Reliability Resource Initiative Additional Summaries · confidence: medium
- Interconnection: Remington CT substation at 230 kV, connected to the Marsh Run CT substation by Dominion Energy 230-kV transmission lines. — Remington - Marsh Run | Dominion Energy · confidence: medium
- Site acres: 72 — Cover Page Template - Cloudfront.net · confidence: medium
- Commercial operation date: 2000 — Power Stations | Dominion Energy · confidence: high
- Product url: https://www.gevernova.com/gas-power/products/gas-turbines/7f — 7f.04 heavy duty gas turbine · confidence: medium
- Equipment models: [{"manufacturer_domain":"gevernova.com","product_url":"https://www.gevernova.com/gas-power/products/gas-turbines/7f","count":4,"unit_mw":null,"name":"GE Power 7F.04 gas turbine"}] — GE Design Gas Turbine Experience, MS7001F/FA · confidence: medium
- Quality notes: ["Capacity figures use different reporting bases: the EIA-derived record lists 705.5 MW of nameplate capacity, while Dominion reports 613.7 MW of net generating capacity.","Operating-date records differ by scope: an EIA-derived record and a plant profile report first-unit or commissioning activity in June 2000, while an EPA petition states that the facility commenced operation in July 2000.","PJM records identify proposed Remington uprates, but the cited records do not establish that those uprates have been completed. No retirement or repowering event is documented.","The available records do not establish a sale of EIA plant 7838, a predecessor owner, seller, transaction consideration, or project-specific construction financing. A 1999 Dominion reference to acquiring Remington Energy, Ltd. concerns a separate Calgary gas producer and is not a transaction for this Virginia power station."] — Petition to Retain Gas-Fired Status for Remington Units 1, 2... · confidence: medium
- Quality notes: ["Capacity figures use different reporting bases: the EIA-derived record lists 705.5 MW of nameplate capacity, while Dominion reports 613.7 MW of net generating capacity.","Operating-date records differ by scope: an EIA-derived record and a plant profile report first-unit or commissioning activity in June 2000, while an EPA petition states that the facility commenced operation in July 2000.","PJM records identify proposed Remington uprates, but the cited records do not establish that those uprates have been completed. No retirement or repowering event is documented.","The available records do not establish a sale of EIA plant 7838, a predecessor owner, seller, transaction consideration, or project-specific construction financing. A 1999 Dominion reference to acquiring Remington Energy, Ltd. concerns a separate Calgary gas producer and is not a transaction for this Virginia power station."] — Reliability Resource Initiative Additional Summaries · confidence: medium
- Quality notes: ["Capacity figures use different reporting bases: the EIA-derived record lists 705.5 MW of nameplate capacity, while Dominion reports 613.7 MW of net generating capacity.","Operating-date records differ by scope: an EIA-derived record and a plant profile report first-unit or commissioning activity in June 2000, while an EPA petition states that the facility commenced operation in July 2000.","PJM records identify proposed Remington uprates, but the cited records do not establish that those uprates have been completed. No retirement or repowering event is documented.","The available records do not establish a sale of EIA plant 7838, a predecessor owner, seller, transaction consideration, or project-specific construction financing. A 1999 Dominion reference to acquiring Remington Energy, Ltd. concerns a separate Calgary gas producer and is not a transaction for this Virginia power station."] — Dominion Finalizes Second Canadian Purchase · confidence: medium
- Financing summary: No project-specific construction financing, refinancing, sale consideration, or portfolio transaction value is disclosed for Remington plant 7838. A 1999 Dominion filing refers to funding the acquisition of Remington Energy, Ltd., while a contemporaneous report identifies that separate company as a Calgary gas producer acquired by Dominion in April 1999 for nearly US$300 million; that transaction should not be attributed to the Remington power plant. — Dominion Finalizes Second Canadian Purchase · confidence: medium
- Quality notes.0: Capacity figures use different reporting bases: the EIA-derived record lists 705.5 MW of nameplate capacity, while Dominion reports 613.7 MW of net generating capacity. — Petition to Retain Gas-Fired Status for Remington Units 1, 2... · confidence: medium
- Quality notes.1: Operating-date records differ by scope: an EIA-derived record and a plant profile report first-unit or commissioning activity in June 2000, while an EPA petition states that the facility commenced operation in July 2000. — Petition to Retain Gas-Fired Status for Remington Units 1, 2... · confidence: medium
- Quality notes.1: Operating-date records differ by scope: an EIA-derived record and a plant profile report first-unit or commissioning activity in June 2000, while an EPA petition states that the facility commenced operation in July 2000. — Power plant profile: Remington Power Station, US · confidence: medium
- Quality notes.2: PJM records identify proposed Remington uprates, but the cited records do not establish that those uprates have been completed. No retirement or repowering event is documented. — Reliability Resource Initiative Additional Summaries · confidence: medium
- Quality notes.3: The available records do not establish a sale of EIA plant 7838, a predecessor owner, seller, transaction consideration, or project-specific construction financing. A 1999 Dominion reference to acquiring Remington Energy, Ltd. concerns a separate Calgary gas producer and is not a transaction for this Virginia power station. — Dominion Finalizes Second Canadian Purchase · confidence: medium
- Timeline.0: {"event":"First unit entered service","date":"2000-06","detail":"The EIA-derived plant record reports the first unit online in June 2000; a plant profile likewise reports post-construction commissioning in June 2000."} — Dominion Finalizes Second Canadian Purchase · confidence: medium
- Timeline.0: {"event":"First unit entered service","date":"2000-06","detail":"The EIA-derived plant record reports the first unit online in June 2000; a plant profile likewise reports post-construction commissioning in June 2000."} — Power plant profile: Remington Power Station, US · confidence: medium
- Timeline.1: {"event":"Facility commenced operation","date":"2000-07","detail":"An EPA petition for the Remington facility states that the four-unit combustion-turbine facility commenced operation in July 2000."} — Petition to Retain Gas-Fired Status for Remington Units 1, 2... · confidence: medium
- Timeline.3: {"event":"PJM reliability-resource uprates selected","date":"2025-05","detail":"PJM’s May 6, 2025 reliability-resource summary lists Remington CT 230 kV projects AH1-684 and AH1-685 as natural-gas uprates with requested in-service year 2028 and 23 MW and 26 MW of capacity, respectively."} — Reliability Resource Initiative Additional Summaries · confidence: medium
- Substation: Remington CT substation — Remington - Marsh Run | Dominion Energy · confidence: high
- Interconnection voltage kv: 230 — Remington - Marsh Run | Dominion Energy · confidence: medium
- Replacement or repowering: Planned change is an uprate, not a replacement or repowering: PJM RRI projects AH1-684 and AH1-685 are 2028 uprates, and AH1-693 is a 2029 uprate. — Reliability Resource Initiative Additional Summaries · confidence: high
- Grid role: Peaking generation — 2024 VA IRP · confidence: high

## Timeline

- 2025-05 — PJM reliability-resource uprates selected
  PJM’s May 6, 2025 reliability-resource summary lists Remington CT 230 kV projects AH1-684 and AH1-685 as natural-gas uprates with requested in-service year 2028 and 23 MW and 26 MW of capacity, respectively.
  Source: Reliability Resource Initiative Additional Summaries (https://www.pjm.com/-/media/DotCom/committees-groups/committees/pc/2025/20250506/20250506-rri-addendum---post-meeting.pdf)
- 2026-05 — Transmission upgrade proposed
  Dominion filed an application on May 12, 2026, to rebuild and upgrade two existing 230 kV transmission lines between the Marsh Run and Remington combustion-turbine substations. This is a transmission reliability project, not evidence of completed generating-unit repowering.
  Source: Remington - Marsh Run | Dominion Energy (https://www.dominionenergy.com/en/About/Delivering-Energy/Electric-Projects/Power-Line-Projects/Remington-Marsh-Run)

## Sources

- [Power Stations | Dominion Energy](https://www.dominionenergy.com/en/About/Making-Energy/Power-Stations) — dominionenergy.com · tier other
- [Plant Name](https://downloads.regulations.gov/EPA-HQ-OAR-2009-0234-3044/content.pdf) — downloads.regulations.gov · tier regulatory
- [Reliability Resource Initiative Additional Summaries](https://www.pjm.com/-/media/DotCom/committees-groups/committees/pc/2025/20250506/20250506-rri-addendum---post-meeting.pdf) — pjm.com · tier other
- [ORIS Crosswalk](https://www.epa.gov/sites/default/files/2017-09/ghgrp_oris_power_plant_crosswalk_8_5_17.xlsx) — epa.gov · tier regulatory
- [Remington - Marsh Run | Dominion Energy](https://www.dominionenergy.com/en/About/Delivering-Energy/Electric-Projects/Power-Line-Projects/Remington-Marsh-Run) — dominionenergy.com · tier other
- [Cover Page Template - Cloudfront.net](https://d2kbkoa27fdvtw.cloudfront.net/fauquier-va/3c979fea111dfe7f62f7d3cd18022ab00.pdf) — d2kbkoa27fdvtw.cloudfront.net · tier other
- [Power plant profile: Remington Power Station, US](https://www.power-technology.com/data-insights/power-plant-profile-remington-power-station-us/) — power-technology.com · tier other
- [7f.04 heavy duty gas turbine](https://www.gevernova.com/content/dam/gepower-new/global/en_US/downloads/gas-new-site/products/gas-turbines/ged7495-7f04-product-poster.pdf) — gevernova.com · tier other
- [GE Design Gas Turbine Experience, MS7001F/FA](https://puc.sd.gov/commission/dockets/electric/2004/EL04-041/7FAExperience%20as%20of%20051404.pdf) — puc.sd.gov · tier regulatory
- [Petition to Retain Gas-Fired Status for Remington Units 1, 2 ...](https://www.epa.gov/sites/default/files/2015-05/documents/remington_combustion_turbine_station.pdf) — epa.gov · tier regulatory
- [Source](https://www.sec.gov/Archives/edgar/data/715957/000071595799000061/0000715957-99-000061-d1.html) — sec.gov · tier regulatory
- [Dominion Finalizes Second Canadian Purchase](https://naturalgasintel.com/news/dominion-finalizes-second-canadian-purchase/) — naturalgasintel.com · tier other
- [10-K](https://www.sec.gov/Archives/edgar/data/103682/000119312519057924/d662998d10k.htm) — sec.gov · tier regulatory
- [2024 VA IRP](https://www.dominionenergy.com/-/media/content/about/our-company/irp/pdfs/2024-irp-w_o-appendices.pdf) — dominionenergy.com · tier other
- [October 15, 2025 BY ELECTRONIC DELIVERY Bernard Logan, Clerk Document Control Center State Corporation Commission 1300 E. Main Street, Tyler](https://www.dominionenergy.com/-/media/content/about/our-company/irp/pdfs/2025-integrated-resource-plan-update.pdf) — dominionenergy.com · tier other

## Data quality

- Capacity figures use different reporting bases: the EIA-derived record lists 705.5 MW of nameplate capacity, while Dominion reports 613.7 MW of net generating capacity. Operating-date records differ by scope: an EIA-derived record and a plant profile report first-unit or commissioning activity in June 2000, while an EPA petition states that the facility commenced operation in July 2000. PJM records identify proposed Remington uprates, but the cited records do not establish that those uprates have been completed. No retirement or repowering event is documented. The available records do not establish a sale of EIA plant 7838, a predecessor owner, seller, transaction consideration, or project-specific construction financing. A 1999 Dominion reference to acquiring Remington Energy, Ltd. concerns a separate Calgary gas producer and is not a transaction for this Virginia power station.

---

Canonical page: https://askthegrid.com/assets/facilities/remington